BUS | FIELDBUS cables for industrial & process automation
SafetyBUS 100 - 120 Ohm
03.10.07.01
|
Use of Cable
as fieldbus cables for SafetyBUS systems for fixed installation & flexible applications, in the field of factory automation.
SafetyBUS is a safe, open fieldbus system, which is optimized for the transmission of data relating to machine safety: timing and content consistency of the data have the highest priority here.
Product information "SafetyBUS 100 - 120 Ohm"
Special features
- largely resistant to grease, coolant fluids and lubricants
- oil-resistant: acc.to DIN EN 60811-2-1 (only mineral oil)
- EMC compliant shielding
- max. cable lengths for a bus segment at stated transmission rate:
50 kbit/s-max.1,0km | 125 kbit/s-max.500m | 250 kbit/s-max.250 m |
0,5Mbit/s-max.100m
- conform to RoHS
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- LABS-/silicone-free (during production)
- FC-Type = 'fast-connect' construction
Conductor material: | Bare copper strand |
---|---|
Conductor class: | 19-wired |
Core insulation: | Foamed polyolefin |
Core identification: | White, brown, green |
Stranding: | Cores stranded in layers |
Inner sheath material: | PVC |
Shield3: | Copper braid tinned |
Outer sheath: | PVC |
Sheath colour: | Yellow RAL 1003 (YE) |
Outer diameter: | 8,0 mm |
Rated voltage: | 250 V (not for high voltage purposes) |
Testing voltage: | 1,5 kV |
Loop resistance: | Max. 26,0 Ω / km |
Capacity: | Nom. 45nF/km |
Characteristic impedance: | 100 - 120 Ω |
Min. bending radius fixed: | 8 x d |
Min. bending radius moved: | 10 x d |
Operat. temp. fixed min/max: | -40 °C / +80 °C |
Operat. temp. moved min/max: | -10 °C / +70 °C |
Burning behavior: | Flame-retardant acc. to IEC 60332-1-2, Cable Flame Test (UL 2556) |
Approvals: | UL/CSA - cURus 300 V, 80 °C |
Copper weight: | 50,0 kg/km |
Weight: | 87,0 kg/km |
There aren't any asked questions yet.
ASi-BUS Aktor Sensor Interface
03.10.06.01
BUS | FIELDBUS cables for industrial & process automation
for fixed installation & limited flexible applications, UL/CSA
for fixed installation & limited flexible applications, UL/CSA
Item count
10
PROFIBUS DP / FMS / FIP 150 Ohm
03.10.01.01
BUS | FIELDBUS cables for industrial & process automation
fixed installation & limited flexible applications, UL/CSA, different CPR versions available
fixed installation & limited flexible applications, UL/CSA, different CPR versions available
Item count
11
MULTIBUS & INTERBUS 100 - 120 Ohm - HF
03.10.02.02
BUS | FIELDBUS cables for industrial & process automation
for high flexible applications (drag chain) UL/CSA
for high flexible applications (drag chain) UL/CSA
Item count
7
DeviceNet 120 Ohm
03.10.04.01
BUS | FIELDBUS cables for industrial & process automation
for fixed installation & limited flexible applications, UL/CSA
for fixed installation & limited flexible applications, UL/CSA
Item count
4