Reelable cables
REELTEC® (K) NSHTÖU, (N)SHTÖU
06.09.13.01
|
Use of Cable
reeling cable for winding operation, especially with tensile stress at the same time and/or torsional stress and/or compulsory cable direction. Suitable for dry, humid and wet rooms, for outdoor use and also on construction sites, in comercial and agricultural plants. For travelling up to 120 m/min.
Product information "REELTEC® (K) NSHTÖU, (N)SHTÖU"
Special features
- free from lacquer damaging substances and silicone (during production)
- for travelling speed up to 120 m / min
- conform to RoHS
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- range of application look at the technical guideline
- We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Conductor material: | Tinned copper strand |
---|---|
Conductor class: | Acc. to DIN VDE 0295 class 5 resp. IEC 60228 cl. 5 |
Core insulation: | Rubber compound |
Core identification: | Acc. to VDE 0293-308 up to 5 wires coloured, from 6 wires black with white numerals with GNYE |
Stranding: | Cores stranded in layers |
Inner sheath material: | Special rubber-compound |
Outer sheath: | Special rubber-compound |
Sheath colour: | Black |
Rated voltage: | Uo/U: 0,6/1 kV |
Testing voltage: | 2,5 kV |
Current-carrying-capacity: | Acc. to DIN VDE, see Technical Guideline |
Min. bending radius fixed: | Acc. to DIN VDE 0298 part 3 |
Min. bending radius moved: | Acc. to DIN VDE 0298 part 3 |
Operat. temp. fixed min/max: | -40 °C / +80 °C |
Operat. temp. moved min/max: | -25 °C / +80 °C |
Temp. at conductor: | +90 °C |
Burning behavior: | Self-extinguishing and flame retardant acc. to IEC 60332-1 |
Resistant to oil: | Acc. to EN60811-404 |
Tensile strength: | Tensile strength max. 20 N / mm² |
Standard: | According or similar to DIN VDE 0250 |
There aren't any asked questions yet.