Use of Cable

The cable is intended for permanent installation in rail vehicles or for applications in which a limited bending stress occur during service.

Product variants
Icon einsatzort indoor
Icon abschirmung Icon merkmale kein feuer Icon merkmale oelresistent Icon merkmale halogenfrei
Icon standards ce geschuetzt Icon standards ul csa
Product information "RADOX® RAILCAT CAT7 4x(2x24AWG) XM S"
Special features
  • Halogen free electron-beam cross linked cable with improved behaviour in case of fire, easy to strip, soldering iron isresistant and flexible. Meet the electrical requirements of EN 50288--4--2 and IEC 61156--6 Cat. 7.The cable is especially suitable for Gigabit Ethernet and for transmission of digital data for applications up to 10 Gigabitaccording to IEEE 802.3.
Remarks
  • conform to RoHS
  • conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
Conductor material: Flexible tin plated copper
Core insulation: RADOX FOAM
Core identification: White/orange, orange, white/green, green, white/brown, brown, white/blue, blue
Shield: Flexible tin plated copper
Inner sheath material: RADOX FOAM
Inner sheath colour: Pairs: (white/orange, orange), (white/green, green), (white/brown, brown), (white/blue, blue)
Shield3: Pair: aluminium tape
Outer sheath: RADOX EM 104
Sheath colour: Blue
Rated voltage: Uo: 125 V
Testing voltage: 1 kV
Characteristic impedance: 100 Ω
Min. bending radius fixed: 4 x d
Min. bending radius moved: 10 x d
Operat. temp. fixed min/max: -50 °C / +70 °C
Operat. temp. moved min/max: -50 °C / +70 °C
Halogen free: Halogen - free acc. EN 50267-2- 1
Corrodibility: Acc. EN 50267- 2- 2
Toxic: Acc. EN 50305
Burning behavior: EN 45545, DIN 5510, NF F16-101, UNI CEI 11170, NFPA 130, BS 6853, GM/RT 2130
Resistant to oil: IRM 902
Standard: Hazard level code M acc. to EN 50264- 1 or EN 50306- 1
Approvals: UL 1685 FT4
RADOX® RAILDAT 120 OHM nx0.5 XM S 26.06.12_JOB
RADOX® RAILDAT 120 OHM nx0.5 XM S
Halogen free, electrom- beam cross- linked cables with improved behaviour in case of fire
Item count 6
RADOX® DATABUS 120 OHM nx0.5 XM S EN 26.06.03_JOB
RADOX® DATABUS 120 OHM nx0.5 XM S EN
Halogen free, electrom- beam cross- linked cables with improved behaviour in case of fire
Item count 6
RADOX® DATABUS 120 OHM nx0.5 XM S 26.06.02_JOB
RADOX® DATABUS 120 OHM nx0.5 XM S
Halogen free, electrom- beam cross- linked cables with improved behaviour in case of fire
Item count 6