RADOX® RAILCAT CAT5e FR | JOB_H+S85078658 | JOB_H+S85078658
Icon static
RADOX® RAILCAT CAT5e FR 100 OHM

RADOX® RAILCAT CAT5e FR

26.06.08_JOB

|

Use of Cable

The cable is intended for fixed installation inside railway vehicles or for installation in applications where limited alternating bending stresses occur during operation.

Product variants
Icon einsatzort indoor
Icon abschirmung Icon merkmale kein feuer Icon merkmale oelresistent Icon merkmale halogenfrei
Icon standards ce geschuetzt
Product information "RADOX® RAILCAT CAT5e FR"
Special features
  • Halogen-free, electron-beam cross-linked cable with improved behaviour in case of fire and maintain circuit integrity, easy to strip,soldering resistant and flexible.
Remarks
  • conform to RoHS
  • conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
Conductor material: Stranded tin plated copper
Core insulation: RADOX COM FR
Core identification: White, blue, yellow, orange
Shield: Tin plated copper braid
Inner sheath material: RADOX COM FR
Inner sheath colour: Pairs: (white, blue) / (yellow, orange)
Shield3: Tin plated copper braid
Outer sheath: RADOX EM 104
Sheath colour: Blue
Rated voltage: Uo: 300 V
Testing voltage: 2 kV
Characteristic impedance: 100 Ω
Min. bending radius fixed: 6 x d
Operat. temp. fixed min/max: -40 °C / +90 °C
Halogen free: Halogen - free acc. EN 60754- 1
Corrodibility: Acc. EN 60754- 2
Toxic: Acc. EN 50305
Burning behavior: EN 50200, EN 50289-4-16, PH30, EN 45545-2, GOST 31565
Resistant to oil: IRM 902
Standard: Hazard level code M acc. to EN 50264- 1 or EN 50306- 1
RADOX® RAILDAT 120 OHM nx0.5 XM S 26.06.12_JOB
RADOX® RAILDAT 120 OHM nx0.5 XM S
Halogen free, electrom- beam cross- linked cables with improved behaviour in case of fire
Item count 6
RADOX® DATABUS 120 OHM nx0.5 XM S EN 26.06.03_JOB
RADOX® DATABUS 120 OHM nx0.5 XM S EN
Halogen free, electrom- beam cross- linked cables with improved behaviour in case of fire
Item count 6
RADOX® DATABUS 120 OHM nx0.5 XM S 26.06.02_JOB
RADOX® DATABUS 120 OHM nx0.5 XM S
Halogen free, electrom- beam cross- linked cables with improved behaviour in case of fire
Item count 6