RADOX® EN 50264-3-1 0,6/1kV M FR
RADOX® EN 50264-3-1 600V M FR
26.07.07_JOB
|
Use of Cable
The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service.
Product information "RADOX® EN 50264-3-1 600V M FR"
Special features
- Halogen free electrom-beam cross-linked cables with improved behaviour in case of fire, easy to strip and flexible.
- conform to RoHS
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
| Conductor material: | Stranded tin plated copper |
|---|---|
| Conductor class: | Acc. to EN 60228 cl. 5 |
| Core insulation: | MICA- tape + RADOX EI 110 |
| Core identification: | White |
| Inner sheath material: | MICA- tape + RADOX EI 110 |
| Inner sheath colour: | White |
| Outer sheath: | RADOX EI 109 |
| Sheath colour: | Black |
| Rated voltage: | Uo/U: 0,6/1 kV |
| Testing voltage: | 3,5 kV |
| Conductor resistance: | Acc. to EN 60228 |
| Min. bending radius fixed: | <12 mm 3 x d >12 mm 4 x d |
| Min. bending radius moved: | <12 mm 4 x d > 12 mm 5 x d |
| Operat. temp. fixed min/max: | -50 °C / +120 °C |
| Operat. temp. moved min/max: | -50 °C / +120 °C |
| Halogen free: | Halogen - free acc. EN 60754- 1 |
| Corrodibility: | Acc. EN 60754- 2 |
| Toxic: | Acc. EN 50305 |
| Burning behavior: | EN 50200, EN 50362, IEC 60331-21, EN 45545, NFPA 130 |
| Resistant to oil: | IRM 902 |
| Standard: | Hazard level code M acc. to EN 50264- 1 or EN 50306- 1 |
| Approvals: | UL 1685 FT4 |
There aren't any asked questions yet.
RADOX® 3 GKW 300V M FR RW
26.07.01_JOB
RADOX® 3 GKW 300/500V M FR RW
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Item count
5
RADOX® 3 GKW 300V MM FR RW
26.07.02_JOB
RADOX® 3 GKW 300/500V MM FR RW
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Item count
19
RADOX® 3 GKW 300V MM S FR RW
26.07.03_JOB
RADOX® 3 GKW 300/500V MM S FR RW
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Item count
28
RADOX® 4 GKW-AX 1800V M FR
26.07.06_JOB
RADOX® 4 GKW-AX 1,8/3kV M FR
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Item count
14