RADOX® Databus CAT7 | JOB_H+S85030430 | JOB_H+S85030430
Icon static
RADOX® Databus CAT7 100 Ω

RADOX® Databus CAT7

23.06.02_JOB

|

Use of Cable

This ethernet databus is specially designed for applications in harsh environment.

Product variants
Icon einsatzort indoor
Icon abschirmung Icon merkmale kein feuer Icon merkmale halogenfrei
Icon standards ce geschuetzt
Product information "RADOX® Databus CAT7"
Special features
  • Halogen free electron--beam cross linked cable with improved behaviour in case of fire, easy to strip, soldering iron isresistant and flexible. Meet the electrical requirements of EN 50288--4--2 and IEC 61156--6 Cat. 7. Stripped wires helps tobetter difference by assembling.The cable is especially suitable for Gigabit Ethernet and for transmission of digital data for applications up to 10 Gigabitaccording to IEEE 802.3.
Remarks
  • conform to RoHS
  • conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
Conductor material: Flexible tin plated copper
Core insulation: RADOX FOAM
Core identification: Different colours
Shield: Pairs in aluminium clad foil, cover. 100%
Overall stranding: Cores or pairs stranded in layers
Inner sheath material: RADOX FOAM
Inner sheath colour: Different colours
Outer sheath: RADOX REMS FH
Sheath colour: Black or blue
Rated voltage: Uo: 125 V
Testing voltage: 1 kV
Conductor resistance: Max 95 Ω / km
Characteristic impedance: 100 Ω ± 5 Ω
Min. bending radius fixed: 4 x d
Operat. temp. fixed min/max: -50 °C / +125 °C
Operat. temp. moved min/max: -40 °C / +125 °C
Corrodibility: Acc. EN 50267- 2- 1
Toxic: Acc. EN 50305
Burning behavior: EN 60332
Standard: EN 50288--4--2 and IEC 61156--6 Cat. 7
RADOX® Databus CAT7 23.06.02_JOB
RADOX® Databus CAT7 100 Ω
Halogen free electron--beam cross linked cable with improved behaviour in case of fire. Meet the electrical requirements of EN 50288--4--2 and IEC 61156--6 Cat. 7
Item count 2
RADOX® Marine Databus 120 OHM 23.06.03_JOB
RADOX® Marine Databus 120 Ω
Halogen free, flame retardant, high temperature, low temperature and ozone resistance
Item count 6