RADOX® 3 GKW 0,6/1kV FR
RADOX® 3 GKW 600V FR
26.07.04_JOB
|
Use of Cable
The cables are intended for permanent installation in rail vehicles.
Product information "RADOX® 3 GKW 600V FR"
Special features
- Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity , easyto strip, soldering resistant and flexible.
- conform to RoHS
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
Conductor material: | Stranded tin plated copper |
---|---|
Conductor class: | Acc. to EN 60228 cl. 5 |
Core insulation: | MICA- tape + <6 mm2 RADOX EI 109 or 6> mm2 RADOX EI 201 |
Core identification: | Grey marking black |
Inner sheath material: | MICA- tape + <6 mm2 RADOX EI 109 or 6> mm2 RADOX EI 201 |
Inner sheath colour: | Grey marking black |
Outer sheath: | <6 mm2 RADOX EI 109 or 6> mm2 RADOX EI 201 |
Sheath colour: | Grey |
Rated voltage: | Uo/U: 0,6/1 kV |
Testing voltage: | 3,5 kV |
Conductor resistance: | Acc. to IEC 60228 |
Min. bending radius fixed: | <12 mm 3 x d >12 mm 4 x d |
Operat. temp. fixed min/max: | -50 °C / +120 °C |
Halogen free: | Halogen - free acc. EN 60754- 1 |
Corrodibility: | Acc. EN 60754- 2 |
Toxic: | Acc. EN 50305 |
Burning behavior: | EN 50200, EN 45545, NFPA 130 |
Approvals: | UL 1685 FT4 |
There aren't any asked questions yet.
RADOX® 3 GKW 300V M FR RW
26.07.01_JOB
RADOX® 3 GKW 300/500V M FR RW
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Item count
5
RADOX® 3 GKW 300V MM FR RW
26.07.02_JOB
RADOX® 3 GKW 300/500V MM FR RW
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Item count
19
RADOX® 3 GKW 300V MM S FR RW
26.07.03_JOB
RADOX® 3 GKW 300/500V MM S FR RW
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Item count
28
RADOX® 4 GKW-AX 1800V M FR
26.07.06_JOB
RADOX® 4 GKW-AX 1,8/3kV M FR
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Halogen free, electron- beam cross- linked cores with improved behaviour in case of fire and maintains circuit integrity
Item count
14