Use of Cable

as fieldbus cable for PROFIBUS (Process Field BUS) PA (Process Automation) systems, specifically for use in process automation as well as in hazardous areas to connect sensors and actuators, for fixed installation & limited flexible applications.



Standard acc.to Profibus-Spec.: EN61158 & EN61784 (DIN19245 T3 & EN50170)

Product variants
Icon einsatzort indoor Icon einsatzort outdoor
Icon abschirmung Icon merkmale uv resistent Icon merkmale kein feuer Icon merkmale oelresistent
Icon standards ce geschuetzt Icon standards ul csa
Product information "PROFIBUS PA 100 Ohm"
Special features
  • largely resistant to grease, coolant fluids and lubricants
  • oil-resistant: acc.to DIN EN 60811-2-1 (only mineral oil)
  • UV-resistant: all PA TRAY versions (blue & black) &
                         versions with black outer sheath
  • optimized EMC compliant shielding
  • PA TRAY with UL/CSA approval:
                  cULus: 300 V, 75 °C, CMG/PLTC/SunRes/OilRes &
                  cURus: 600 V, 60 °C
Remarks
  • conform to RoHS
  • LABS-/silicone-free (during production)
  • FC-Type = 'fast-connect' construction
  • PI = Profibus & Profinet International
  • conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
Conductor material: Bare copper strand
Conductor class: 1,0 mm²: fine-wired acc. IEC 60228 cl. 5; AWG18: single wire
Core insulation: Foamed PE/PP
Core identification: Gn, rd
Stranding: BUScores stranded to a pair
Shield3: Copper braid tinned; TRAY: alu-lamin. polyester foil, metal side outside, cover. 100% under copper braid tinned
Outer sheath: PVC
Sheath colour: Blue RAL 5015 (BU) or black (BK)
Rated voltage: 250 V (not for high voltage purposes)
Testing voltage: 1,5 kV
Loop resistance: 39,0 Ω/km - 1,0 mm²; max. 36,4 Ω/km - AWG 18/1
Capacity: Nom. 52 nF/km
Characteristic impedance: 100 Ω ± 20 Ω
Min. bending radius fixed: 7,5 x d
Min. bending radius moved: 15 x d
Operat. temp. fixed min/max: -40°C / +80°C
Operat. temp. moved min/max: -10°C / +70°C
Burning behavior: Flame retardant, acc. to IEC 60332-1-2 resp. CMG: acc. to IEC 60332-3-24(Cat.C), FT 4
Resistant to oil: Acc. to DIN EN 60811-2-1 (only mineral oil)
Approvals: PA TRAY: UL/CSA - cULus 300V, 75°C, CMG/PLTC/SunRes/OilRes & cURus 600V, 60°C
ASi-BUS Aktor Sensor Interface 03.10.06.01
BUS | FIELDBUS cables for industrial & process automation
for fixed installation & limited flexible applications, UL/CSA
Item count 10
PROFIBUS DP / FMS / FIP 150 Ohm 03.10.01.01
BUS | FIELDBUS cables for industrial & process automation
fixed installation & limited flexible applications, UL/CSA, different CPR versions available
Item count 11
MULTIBUS & INTERBUS 100 - 120 Ohm - HF 03.10.02.02
BUS | FIELDBUS cables for industrial & process automation
for high flexible applications (drag chain) UL/CSA
Item count 7
DeviceNet 120 Ohm 03.10.04.01
BUS | FIELDBUS cables for industrial & process automation
for fixed installation & limited flexible applications, UL/CSA
Item count 4