Halogen-free lift cables
LIFTTEC® multiCAT.7 - H-LC
06.06.05.01
|
Use of Cable
Flat, flexible travelling Ethernet cable for networking purposes according to Cat.7 speci-fications in passenger and goods lifts (elevators).
Standard acc. Industrial Ethernet Spec. & according the requirements for industrial se-condary and tertiary cabling: EN 50173, ISO/IEC 11801, ISO/IEC 24702, TIA/EIA 568, TSB36, EN 50288, IEC 61156-5/-6, IEEE 802.3af.
Product information "LIFTTEC® multiCAT.7 - H-LC"
Special features
- low adhesion
- largely resistant to grease, coolant fluids and lubricants
- oil-resistant: acc. to IEC 60811-404
- optimized EMC compliant shielding
- low adhesionlow attenuation
- high crosstalk attenuation
- 4 pairs: 10Gbit/s (Cat.7) for Industrial Ethernet
- HF-characteristics Cat.7 acc.to IEC 61156-6 (7-wired)
- Ripcords for easy removing sheath material
- Conform to RoHS // LABS-/silicone-free (during production)
- Conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- FRNC: Flame Retardant, Non Corrosive
- 7-wired: for patch cable applications (max 60m.)
- Available accessories can be found under the section 15.35.XX
Conductor material: | Bare copper strand |
---|---|
Conductor class: | 7-wired AWG 26/7 (0,14mm²) |
Core insulation: | PE |
Core identification: | Whbu-bu, whog-og, whgn-gn, whbn-bn |
Stranding: | Cores twisted to pairs |
Shield: | S/FTP: copper braid tinned as overall shield & alu-lamin. polyester foil as pair shield |
Supporting element: | 2 steel supporting elements in the outer sheath |
Inner sheath material: | Halogen-free compound, grey |
Outer sheath: | Halogen-free compound, with ripcords |
Outer sheath construction: | Surface with knurling |
Sheath colour: | Black, RAL 9005 |
Rated voltage: | 30 V |
Testing voltage: | 1 kV |
Conductor resistance: | Max. 143 Ω / km |
Loop resistance: | 292 Ω / km |
Insulation resistance: | ≥ 2.000 MΩ x km |
Capacity: | Nom. 43 nF / km |
Characteristic impedance: | 100 ± 5 Ω (100 MHz) |
Transfer rate: | Cat.7 acc. to. DIN EN 50288-4-2 |
Attenuation: | Nach IEC 61156-6 |
Signal propagation delay: | Approx. 4,6 ns / m |
Min. bending radius fixed: | 8 x d |
Min. bending radius moved: | 10 x d |
Operat. temp. fixed min/max: | -15 °C / +70 °C |
Operat. temp. moved min/max: | -15 °C / +60 °C |
Halogen free: | Acc. to IEC 60754-2 |
Burning behavior: | Acc. to IEC 60332-1-2 |
Resistant to oil: | Acc. to IEC 60811-404 |
Suspension height: | Max. 100 m |
Standard: | Based on EN 50214 |
Speed: | Max. 4,0 m/s |
There aren't any asked questions yet.
LIFTTEC® K12YSTU11Y
06.06.01
Halogen-free lift cables
300/500V, unshielded, halogen-free, textile supporting element
300/500V, unshielded, halogen-free, textile supporting element
Item count
2
LIFTTEC® K9YSTFU11Y, K9YSTCU11Y
06.06.02
Halogen-free lift cables
300/500V, element shielded, halogen-free, textile supporting element
300/500V, element shielded, halogen-free, textile supporting element
Item count
7