EQ CY Eca | JOB_T0500527 | JOB_T0500527
Icon static Icon flexible
Electronic cables

EQ CY Eca

02.01.02_JOB

|

Use of Cable

data transmission cable, control and connecting cable predominantly for transmission of analog and digital signals in process controlled facilities in measurement and control technology for lossless transmission of datas and signals. For fixed laying and flexible applications with undefined cable routing and without tensile stress. Suitable for use in dry and humid rooms. Outdoor use only with UV-protection, no laying underground.

Product variants
Icon einsatzort indoor
Icon abschirmung Icon merkmale kein feuer Icon merkmale oelresistent
Icon standards ce geschuetzt Icon standards cpr e ca
Product information "EQ CY Eca"
Special features
  • largely resistant to acids, bases and specified types of oil
  • LABS-/silicone-free (during production)
  • recommended for EMC-applications
Remarks
  • conform to RoHS
  • conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
  • We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Conductor material: Bare copper strand
Conductor class: Acc. to IEC 60228 cl. 5; exception: 0,34 mm², stranded (7 x 0,25 mm)
Core insulation: PVC
Core identification: Acc. to DIN 47100 different colours
Stranding: Stranded in layers
Shield3: Copper braid tinned, coverage approx. 85%
Outer sheath: PVC
Sheath colour: Grey, RAL 7001; LIYCY single core: grey RAL 7001 or transparent
Rated voltage: Uo/U: 250 V; peak-voltage on 0,14 mm² 350 V; > 0,14 mm² 500 V
Testing voltage: On 0,14 mm² core/core: 1,2 kV; core/shield: 1,0 kV > 0,14 mm²: core/core: 1,5 kV; core/shield: 1,0 kV
Conductor resistance: Acc.to IEC 60228 cl. 5
Insulation resistance: Min. 20 MΩ x km
Current-carrying-capacity: Acc. to DIN VDE, see Technical Guidelines
Capacity: Core/core ca. 120 nF/km; core/shield ca. 160 nF/km
Min. bending radius fixed: Up to 12 mm Ø 5 x d; up to 20 mm Ø 7,5 x d; > 20 mm Ø 10 x d
Min. bending radius moved: Up to 12 mm Ø 10 x d; up to 20 mm Ø 15 x d; > 20 mm Ø 20 x d
Operat. temp. fixed min/max: -30 °C / +80 °C
Operat. temp. moved min/max: -5 °C / +70 °C
Burning behavior: Self-extinguishing & flame-retardant acc.to IEC 60332-1
Standard: Similar to DIN VDE 0812