BUS | FIELDBUS cables for industrial & process automation
DeviceNet 120 Ohm
03.10.04.01
|
Use of Cable
as fieldbus cables for DeviceNet™ systems in the field of production automation for reliable data and energy transmission (e.g. between sensors, actuators and controllers), for fixed installation & flexible applications.
DeviceNet™ is an Allen Bradley (Rockwell Automation) developed, based on proven CAN technology bus system.
Standard acc. ODVA specifications
Product information "DeviceNet 120 Ohm"
Special features
- largely resistant to grease, coolant fluids and lubricants
- oil-resistant: acc. to DIN EN 60811-2-1 (only mineral oil)
- UV-resistant
- optimized EMC compliant shielding
- max. cable lengths for a bus segment at stated transmission rate as
supply cable:
Trunk - thick: 125 kbit/s-max.500m | 250 kbit/s-max.250m | 0,5 Mbit/s-max.100m
Drop - thin : 125 kbit/s-max.100m | 250 kbit/s-max.100m | 0,5 Mbit/s-max.100m
- conform to RoHS
- conform to DESINA (violet)
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- LABS-/silicone-free (during production)
- ODVA - Open DeviceNet Vendors Association
Conductor material: | Copper strand tinned |
---|---|
Conductor class: | 19-wired |
Core insulation: | BUScores: foamed PE, supply cores: PVC |
Core identification: | BUScores: bu, wh; supply cores: rd, bk |
Stranding: | Cores twisted to pairs |
Shield: | Pairs in aluminium clad foil, cover. 100% |
Overall stranding: | Pairs stranded in layers |
Shield3: | Copper braid tinned, with subjacent tinned drain wire |
Outer sheath: | PVC |
Sheath colour: | Violet RAL 4001 (VT) or grey RAL 7001 (GY) |
Rated voltage: | 300 V (not for high voltage purposee) |
Testing voltage: | 1,5 kV |
Loop resistance: | Max. 181,8 Ω/km - AWG24, max. 114,8 Ω/km - AWG22, max. 45,4 Ω/km - AWG18, max. 22,6 Ω/km - AWG15 |
Capacity: | Nom. 40 nF/km |
Characteristic impedance: | 120 Ω +/- 12 Ω |
Min. bending radius fixed: | 7,5 x d |
Min. bending radius moved: | 15 x d |
Operat. temp. fixed min/max: | -40 °C / +80 °C |
Operat. temp. moved min/max: | -10 °C / +70 °C |
Burning behavior: | Flame retardant acc. to IEC 60332-3-24(Cat.C),FT4 |
Resistant to oil: | Acc. to DIN EN 60811-2-1 (only mineral oil) |
Approvals: | UL/CSA - (Trunk Cable) cULus 300V, 75°C, CMG/PLTC/SunRes/OilRes & cURus 600V, 60°C | (Drop Cable) cULus 300V, 75°C, CMG/CL2/SunRes/OilRes & cURus 600V, 60°C |
There aren't any asked questions yet.
ASi-BUS Aktor Sensor Interface
03.10.06.01
BUS | FIELDBUS cables for industrial & process automation
for fixed installation & limited flexible applications, UL/CSA
for fixed installation & limited flexible applications, UL/CSA
Item count
10
PROFIBUS DP / FMS / FIP 150 Ohm
03.10.01.01
BUS | FIELDBUS cables for industrial & process automation
fixed installation & limited flexible applications, UL/CSA, different CPR versions available
fixed installation & limited flexible applications, UL/CSA, different CPR versions available
Item count
11
MULTIBUS & INTERBUS 100 - 120 Ohm - HF
03.10.02.02
BUS | FIELDBUS cables for industrial & process automation
for high flexible applications (drag chain) UL/CSA
for high flexible applications (drag chain) UL/CSA
Item count
7
DeviceNet 120 Ohm
03.10.04.01
BUS | FIELDBUS cables for industrial & process automation
for fixed installation & limited flexible applications, UL/CSA
for fixed installation & limited flexible applications, UL/CSA
Item count
4