BUS | FIELDBUS cables for industrial & process automation
CAN BUS - ControlerAreaNetwork 120 Ohm - HF
03.10.03.02
|
Use of Cable
as fieldbus cables for CAN (Controller Area Network) systems, in the field of factory automation, for high flexible applications (e.g. power chains, gantry robots, pick&place units, conveyors, machine tools, automated production systems, etc.)
This bussystem has its origins in the automotive sector and has established itself in the field of production automation.
Standard acc. to CAN Spec.: ISO 11898
Product information "CAN BUS - ControlerAreaNetwork 120 Ohm - HF"
Special features
- low adhesion
- largely resistant to grease, coolant fluids and lubricants
- oil-resistant: acc. to DIN EN 60811-2-1
- UV-resistant
- EMC compliant shielding
- max. transmission rate: 1 Mbit/s at 40m segment length
- max. cable lengths for a bus segment depending on the cross section
0- 40 m AWG24, AWG22 | 40-300 m AWG22, AWG20 |
300-600 m AWG20 | 600-1.000 m AWG19
- conform to RoHS
- conform to DESINA (violet)
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- LABS-/silicone-free (during production)
- FRNC: Flame Retardant Non Corrosive, halogen free
Conductor material: | Copper conductor blank |
---|---|
Conductor class: | Super fine wire acc. to IEC 60228 cl. 6 |
Core insulation: | Foamed PE/PP |
Core identification: | Acc. to DIN 47100 |
Stranding: | Cores twisted to pairs |
Shield3: | Copper braid tinned |
Outer sheath: | PUR |
Sheath colour: | Violet RAL 4001 (VT) |
Rated voltage: | 250 V (not for high voltage purposes) |
Testing voltage: | 1,5 kV |
Loop resistance: | Max. 175,2 Ω/km - AWG 24, max. 110,8 Ω/km - AWG 22; max. 68,8 Ω/km - AWG 20; max 55,0 Ω/km - AWG 19 |
Capacity: | Nom. 40 nF/km |
Characteristic impedance: | 120 Ω +/- 12 Ω |
Min. bending radius fixed: | 5 x d |
Min. bending radius moved: | 7,5 x d < 3mTL* | 15 x d ≥ 3mTL* |
Operat. temp. fixed min/max: | -40 °C / +80 °C |
Operat. temp. moved min/max: | -30°C / +70°C |
Halogen free: | Acc. to IEC 60754-1 (FRNC Typen) |
Burning behavior: | Flame-retardant acc. to IEC 60332-1-2, VW-1 |
Resistant to oil: | Acc. to DIN EN 60811-2-1 |
Approvals: | UL/CSA - cULus 300V, 75°C, CMX |
Speed: | Self-supporting: 4 m/s |
Acceleration: | Max. 5 m/s² |
Bending cycles: | Up to 7,5 Mio. |
There aren't any asked questions yet.
ASi-BUS Aktor Sensor Interface
03.10.06.01
BUS | FIELDBUS cables for industrial & process automation
for fixed installation & limited flexible applications, UL/CSA
for fixed installation & limited flexible applications, UL/CSA
Item count
10
PROFIBUS DP / FMS / FIP 150 Ohm
03.10.01.01
BUS | FIELDBUS cables for industrial & process automation
fixed installation & limited flexible applications, UL/CSA, different CPR versions available
fixed installation & limited flexible applications, UL/CSA, different CPR versions available
Item count
11
MULTIBUS & INTERBUS 100 - 120 Ohm - HF
03.10.02.02
BUS | FIELDBUS cables for industrial & process automation
for high flexible applications (drag chain) UL/CSA
for high flexible applications (drag chain) UL/CSA
Item count
7
DeviceNet 120 Ohm
03.10.04.01
BUS | FIELDBUS cables for industrial & process automation
for fixed installation & limited flexible applications, UL/CSA
for fixed installation & limited flexible applications, UL/CSA
Item count
4